We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Signal Processing.
ipros is IPROS GMS ・ IPROS One of the largest technical database sites in Japan that collects information on.

Signal Processing Product List and Ranking from 6 Manufacturers, Suppliers and Companies | IPROS GMS

Last Updated: Aggregation Period:Sep 09, 2026~Oct 06, 2026
This ranking is based on the number of page views on our site.

Signal Processing Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 09, 2026~Oct 06, 2026
This ranking is based on the number of page views on our site.

  1. Edic-Systems Kanagawa//Industrial Electrical Equipment
  2. メディカルトライシステム Tokyo//others
  3. MICRONIX Tokyo//Industrial Electrical Equipment
  4. 4 インターマインド Kanagawa//Industrial Electrical Equipment
  5. 4 クリエイティブ・デザイン Hyogo//Electronic Components and Semiconductors

Signal Processing Product ranking

Last Updated: Aggregation Period:Sep 09, 2026~Oct 06, 2026
This ranking is based on the number of page views on our site.

  1. High-speed signal processing with 16 parallel NCOs Edic-Systems
  2. EEG/ECG/EMG/Trigger/Special Order Analysis, etc. Biological Signal Processing メディカルトライシステム
  3. We respond to customization of biological signal processing and analysis [in-house development]. メディカルトライシステム
  4. Biological signal processing such as brain waves/ECG/EMG/trigger detection/custom analysis, etc. メディカルトライシステム
  5. 4 Signal processing of π/4 QPSK in ETC/DSRC MICRONIX

Signal Processing Product List

1~8 item / All 8 items

Displayed results

Out-of-band signal processing

Enables management and maintenance of edge devices even when hardware or software is not functioning properly.

For more details, please refer to the PDF document or feel free to contact us. Innodisk's remote management technology enables independent connections to flash storage on edge devices. Even when the device's normal network connection is completely unavailable, access to the device can be achieved through a separately secured communication channel.

  • Other electronic parts
  • Memory
  • SSD
  • Signal Processing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

High-speed signal processing with 16 parallel NCOs

This is an NCO that increases the sampling frequency by 16 times by simultaneously outputting 16 points of sin/cos in one clock cycle.

1. What is NCO NCO (Numerical Controlled Oscillator) is a mechanism that generates sin/cos waves using digital circuits. The output frequency is determined by the increment amount (phiinc). 2. Challenges of Conventional Type The conventional type can only output one sample per clock. The maximum output frequency is half of the clock frequency (fclk / 2). To create high-frequency signals, the only option is to increase the clock speed. 3. Concept of 16 Parallel In one clock, 16 samples (x00 to x15) are output simultaneously. The samples are arranged in chronological order, and the sampling frequency is 16 times the clock frequency (16 × fclk). 4. How to Create Phase The phase of lane k is "reference phase + k × phiinc." The reference phase is created by adding phiinc to the phase of the last lane (x15) from the previous clock. Therefore, the waveform does not break at the clock boundary. 5. Circuit Configuration Input register → Constant multiplication (×0 to ×15) → Addition → Phase register → DDS IP ×16 in that order. The phase loop generates the reference phase for the next clock.

  • Embedded system design service
  • Other embedded systems (software and hardware)
  • Communications
  • Signal Processing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Signal processing of π/4 QPSK in ETC/DSRC

Technical Data: ETC/DSRC Testing Equipment

【Product Introduction】 ■DSRC On-Board Unit Tester ME9100 Tests whether the DSRC on-board unit installed in the vehicle communicates normally at the radio level. ■DSRC Communication Unit ME9115 Performs WCN reading of the DSRC on-board unit and measures the electric field strength of the DSRC roadside unit and the on-board unit. ■*For more details, please refer to the PDF document or feel free to contact us. 1. Signal processing of π/4 QPSK in ETC/DSRC 2. Transmission system circuit 3. Reception system circuit

  • Other electronic measuring instruments
  • Signal Processing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

IMF240 Active Filter

A filter that limits the frequency band, allowing only the necessary bandwidth to pass through and helping to reduce noise! [Custom specifications available] Please consult with us.

This is a product from our IMF series of filters. Since it is an analog filter, it has low noise and is composed of a high-pass filter and a low-pass filter. You can select HPF + LPF, LPF, or THRU using a switch. It is compact and lightweight, making it highly portable. We offer custom contract development for low-noise circuits, analog circuits, filter circuits, signal processing circuits, and circuit design. Please feel free to contact us. *You can view the instruction manual and company information by downloading the PDF below.

  • Other electronic measuring instruments
  • Signal Processing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

We respond to customization of biological signal processing and analysis [in-house development].

[Biological Signal Processing Program] We will customize general-purpose software to suit your research.

scopeOn supports your collection, measurement, and analysis of biological signals! ■ We provide the necessary environment for analyzing brain waves (EEG), electromyography (EMG), electrocardiography (ECG), and polygraph data. ■ It can be utilized in a wide range of diverse experiments, including animal testing. ■ We can accommodate special analytical processing based on research papers, such as electromyography analysis, evoked potential analysis, autonomic nervous system analysis (ECG and blood pressure), and multi-phenomenon recording analysis. ■ Additional control functions for electrical stimulation, visual stimulation, auditory stimulation, etc., can be added for evoked potential measurement. ■ As a self-developed product, we can create systems tailored to your needs, such as building an easy-to-use system that integrates with your existing system at a low cost or updating systems that are no longer supported while maintaining their usability.

  • Other analysis software
  • Other Data Loggers
  • Signal Processing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Biological signal processing such as brain waves/ECG/EMG/trigger detection/custom analysis, etc.

[Biological Signal Processing Program] We will customize general-purpose software to suit your research.

scopeOn (Scorpion) supports your collection, measurement, and analysis of biological signals! ■ We provide the necessary environment for analyzing brain waves (EEG), electromyography (EMG), electrocardiography (ECG), and polygraphs. ■ It can be utilized in a wide range of diverse experiments, including animal experiments. ■ We can accommodate special analytical processing based on research papers, such as electromyography analysis, evoked potential analysis, autonomic nervous system analysis (ECG and blood pressure), and multi-phenomenon recording analysis. ■ For evoked potential measurement, we can also add control functions for electrical stimulation, visual stimulation, auditory stimulation, etc. ■ As a self-developed product, we can create systems tailored to your needs, such as building an easy-to-use system that integrates with your existing system at a low cost or updating systems that are no longer supported while maintaining their usability.

  • Other analysis software
  • Other Data Loggers
  • Signal Processing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Creative Design Signal Processing

We have received high ratings and satisfaction from our customers.

By respecting individuals and building a corporate culture of mutual trust, we aim to harness their abilities to the fullest, create valuable technologies and products, and contribute to society and culture.

  • Other semiconductors
  • Signal Processing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

EEG/ECG/EMG/Trigger/Special Order Analysis, etc. Biological Signal Processing

[Biological Signal Processing Program] We will customize general-purpose software to suit your research.

scopeOn (Scorpion) supports your collection, measurement, and analysis of biological signals! ■ We provide the necessary environment for analyzing brain waves (EEG), electromyograms (EMG), electrocardiograms (ECG), and polygraphs. ■ It can be utilized in a wide range of diverse experiments, including animal experiments. ■ We can accommodate special analytical processing based on research papers, such as electromyogram analysis, evoked potential analysis, autonomic nervous system analysis (ECG and blood pressure), and multi-phenomenon recording analysis. ■ For evoked potential measurements, we can also add control functions for electrical stimulation, visual stimulation, auditory stimulation, etc. ■ As a self-developed product, we can develop systems tailored to your needs, such as building an easy-to-use system that integrates with existing systems you already have at a low cost, or updating systems that are no longer supported while maintaining usability.

  • Other analysis software
  • Other Data Loggers
  • Signal Processing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration